Physical Dimensions

  • 21.9” H x 13.2” W x 9.23” D (555 mm H x 335 mm W x 235 mm D)
  • Weight - 11bs (5kg)

Application

  • Veterinary patients

Power

  • Power Source - External AC power or internal battery
  • AC Power - 100-240VAC, 50/60Hz, <150VA
  • Battery - Rechargeable Lead-Acid; Operating time under the normal condition (1 hour)
  • Operating time after the first alarm of low battery (10 min.)

Environmental

  • Working Temperature: 5-40 C
  • Storage Temperature: 0-65 C
  • Working Humidity: 30-75%
  • Storage Temeprature: ≤80%
  • Operating Altitude: Up to 5,000 meters
  • Hyperbaric Pressure - Up to 405.3 kPa

Performance Specifications

  • Display - 12.1” color TFT, Touch Screen
  • Resolution - 800 x 600 pixels
  • Trace - 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2
  • Indicator - Alarm indicator; Power indicator QRS beep and alarm sound
  • Trend Time - 72 hours
  • Recorder - Built-in, thermal array, 2 channels
  • Record - Width 48mm
  • Recorder - Paper 50mm
  • Record - Speed 25mm/s, 50mm/s
  • OxyCRG - Combines HR, SpO2, and resp. trends into a single graph ECG
  • Input - 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice - I, II, III, aVR, aVF, aVL, V
  • Gain Choice - x0.125, x0.25, x0.5, x1.0, x2.0

Filter

  • Diagnostic mode - 0.05 – 100Hz
  • Monitoring mode - 0.05 – 75Hz
  • Surgical mode - 1 – 20Hz
  • Frequency Characteristic - 0.05-40 Hz
  • ECG Waveforms - 7 channels
  • Penetration Voltage - 4000VAC 50/60Hz
  • Sweep Speed - 12.5, 25 and 50 mm/s
  • HR Display Range - 30-300bpm
  • Accuracy - 1% or 1bpm, whichever is greater
  • S-7 Segment Detection - 7 channels
  • Measurement Range - -2.0mv – +2.0mv
  • Arrhythmia Analysis - 13 types
  • Alarm Limit Range Setting - Upper limit 80-400bpm; Lower limit 20-150bpm

RESP

  • Measure Method - RA-LL impedance
  • Range - 0-120 rpm
  • Accuracy - + 3 rpm
  • Alarm Upper-lower Limit Setting - Upper limit 6-120 rpm, Lower limit 3-120 rpm
  • Sweep Speed - 12.5 and 25 mm/s

NIBP

  • Measuring Technology - Automatic oscillating measurement
  • Cuff Inflating - <30s (0 – 300mmHg, standard adult cuff
  • Measuring Period - AVE<40s
  • Mode - Manual, Auto, STAT
  • Measuring Interval in AUTO Mode - 2 min-4 hrs
  • Pulse Rate Range - 30-250 (bpm)
  • Measuring Range - Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg); Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg)
  • Resolution - 1mmHg
  • Accuracy - Pressure, Maximum Mean error 5mmHg, Max. Standard deviation 8mmHg
  • Overpressure Protection - Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg)
  • Alarm Limit Setting - SYS 50-240 mmHg, DIA 15-180 mmHg

TEMP

  • Range - 0 – 50 C (32 – 122 F)
  • Accuracy - Without sensor
  • Display Resolution - 0.1 C
  • Alarm Upper-lower Limit Setting - Upper limit 0-50 C, Lower limit 0-50 C
  • Channel - 2 channels, provide T1, T2, ΔT
  • Alarm Limit Setting - 10-50 C

Masimo SET SpO2

  • Measuring Range:
    • SpO2: 1~100 %
    • PR: 25~20 %
  • SpO2 Accuracy (non-motion):
    • Adult Pediatric: 70~69%: unspecified
    • Neonate: 70~69 %: unspecified
  • SpO2 Accuracy (motion):
    • Adult Pediatric: 70~69% : unspecified
    • Neonate: 70~69 % : unspecified
  • PR Accuracy (non-motion):
    • Adult Pediatric Neonate: 25?240 bpm: ±3 bpm
  • PR Accuracy (motion):
    • Adult Pediatric Neonate: 25<span 20.8px;"="">~240 bpm: ±5 bpm
  • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5
    • SpO2: ±2 %
    • PR: ±3 bpm
  • Modes:
    • Averaging mode: 2,4,8,10,12,14 and 16 s
    • Sensitivity: Normal, APOD and Maximum

IBP (Option)

  • Measurement Range - -10-300mmHg
  • Channel - 2 channels
  • Pressure Transducer Sensitivity, 5μV/V/mmHg
  • Impedance Range - 300-3000Ω
  • Transducer Sites - ART, PA, CVP, RAP, LAP, ICP
  • Resolution - 1mmHg
  • Accuracy - 1mmHg or 2%, whichever is greater
  • Alarm range - -10-300mmHg

EtCO2 (Option) (Respironics)

  • Mode of Sampling - Sidestream
  • Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
  • CO2 Measurement Range - 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
  • CO2 Calculation Method - BTPS (Body Temperature Pressure Saturated)
  • CO2 Resolution - 0.1mmHg(0-69mmHg); 0.25mmHg(70-150mmHg)
  • CO2 Accuracy - 0-40 mmHg 2 mmHg; 41-70 mmHg 5% of reading; 71-100 mmHg 8% of reading; 101-150 mmHg 10% of reading; Above 80 breath per minute 12% of reading
  • Sampling Rate - 100Hz
  • Respiration Rate - 2-150 bpm
  • Respiration Rate Accuracy - 1 breath
  • Response Time - <3 seconds - includes transport time and rise time
  • Inspired CO2 Measurement Range - 3-50 mmHg